Automated data collection

  • AMS B2x-Fx for active, reactive and apparent energy, multirate, with RTC and data profiles AMS B2x-Fx for active, reactive and apparent energy, multirate, with RTC  and data profiles
    Single-phase static electricity meters AMS B2x-Fx are determined for measurement of active, reactive and apparent energy, instantaneous active, reactive and apparent maximum demand, voltage, current and P.F. in 2-wire networks in direct connection. They enable measurement of energy in rates controlled by internal clock (up to 4 rates) or externally controlled in two rates. The measured values stored in registers according to the OBIS codes are displayed on LCD in cyclic or stepping mode. The electricity meters can be parametrized and readout by using optical probe AMOS type and software supplied by the manufacturer. The testing pulses are signalling by a red LEDs separately for active and reactive energy. The meters can be produced in version with measurement in summary mode (unidirectional register) or with measurement in separation mode (consumption – supply).
  • AMT B2x-Fx (active, reactive and apparent en.), multirate, comm. modules, SCS, up to 65, 100 and 120 A AMT B2x-Fx (active, reactive and apparent en.), multirate, comm. modules, SCS, up to 65, 100 and 120 A
    Three-phase multifunctional static electricity meters AMT B2x-Fx4TxIx are determined for measurement of active, reactive and apparent electric energy, instantaneous active, reactive and apparent power for consumption and supply, maximum demand for active, reactive and apparent energy, voltage, current and power factor in 3-phase 4-wires networks in direct and semidirect connection. They enable measurement of energy in rates controlled by internal clock (up to 4 rates) or externally controlled in two rates. The measured values stored into special registers according to the OBIS codes are displayed on LCD in cyclic or step mode. The electricity meters can be parametrized and readout by using optical probe AMOS type and software supplied by the manufacturer. The test pulses are indicated by red LEDs, they are proportional to the active and reactive consumed energy. Electricity meters can be produced in version with summary measuring mode (unidirectional register) or in version with separate mode (consumption - supply).
  • Electricity meter handling system MHS & FHS Electricity meter handling system MHS & FHS
    The meter handling systems MHS & FHS are composed of a set of movable trolleys and fixed stands network. They are utilized for convey and connection of tested meters for technological operations.
  • Software for readout and parametrization AMsoft Software for readout and parametrization AMsoft
    The program is designed for static meters operation either with simple registers or with smart, programmable functions. For programming there are used PCs (the ports COM, USB), where the communication interfaces are connected for performance of serial two-way communication in accordance with IEC/EN 62056-21.
  • Optical communication probes AMOS-USB, AMOS-232P with USB and RS 232 interfaces Optical communication probes AMOS-USB, AMOS-232P with USB and RS 232 interfaces
    Optical probes AMOS-USB and AMOS-232P are used for local serial communication (readout, parametrizing and setting) using infrared communication between static smart electricity meters (meters or other equipment) with optical interface on one side and a PC or HHU (Hand-Held Units) on the other. The probe parameters fulfill all technical requirements on data transmission in accordance with the standard STN EN 62056-21 (previous edition STN EN 61107) and the set of users’ requirements DLMS/COSEM.
  • Optical probes AMOS-RS485x with RS485 interface Optical probes AMOS-RS485x with RS485 interface
    Optical probes AMOS-RS485x are used for serial communication (readout, parametrizing and setting) using infrared communication between static smart electricity meters (or other equipment) with optical interface on one side and PC or RPT (manual computer terminal) equipped with RS485 interface on the other side.
  • AMCV M4x, Mesh/RS485 converter AMCV M4x, Mesh/RS485 converter
    Converters Mesh/RS485 of AMCV M4x type are designed for collection of data from electricity meters in the distribution network equipped with RS485 interface and for their subsequent sending to the Mesh network.
  • AMCV MU-CG, Mesh/USB converter AMCV MU-CG, Mesh/USB converter
    Converters Mesh-gateway/USB of AMCV MU-CG are designed for collection of data from electricity meters in the distribution network, mainly in case of creating of small local networks within AMR systems.
  • Converter AMCV U4, converter USB/RS485 Converter AMCV U4, converter USB/RS485
    Converters AMCV U4 are used for serial communication (readout, parametrizing and setting) using infrared communication between static smart electricity meters (or other equipment) with RS485 interface on one side and PC or RPT (manual computer terminal) equipped with USB interface on the other side.
  • Concentrators AMKR Concentrators AMKR
    The AMKR device is a simple microserver designed for regular data collection from electricity meters (AMR system) and then upload to an FTP server for further processing. An additional function is the automatic processing of all collected data into own database, thus ensuring a backup of the data and allows the user to check, view or monitor the collected data in a presentation form (tables, graphs, statuses).